This howto will step you through the process of setting up the required software to be able to check the status of a compaq or hp smart array and the attached physical and logical drives on centos 6 or rhel. Most servers are installed with older kernels and cciss drivers however, new servers are installed with newer kernel 2. Generate hp adu disk report in esxi host techcrumble. Monitoring compaq or hp smart array raid status on centos.
Manage an hp smart array directly from vmware esxi virtual to. May 21, 2012 wow just stumbled into this one today as i was dreading having to reboot my esxi 4. Some software requires a valid warranty, current hewlett packard enterprise support contract, or a. Vmware desktop clients windows, mac, and ubuntu linux. Manage an hp smart array directly from vmware esxi virtual. Will be running the install from the esxi command line over an ssh terminal if that makes any difference. So, since hp has always had management software for their raid controllers available for windows or linux, i went to check if there was some possibilities also for vmware esxi. This zip file contains 3 different utilities hponcfg, hpbootcfg and hpacucli utilities for remote. Options for using hpe customizations for vmware esxi. Binary royale is an it consultancy company based in the east midlands. When we come across issues that would be useful to others we try to post the answers on our website.
You must install these softwares from esxis shell so ssh service must be enabled. The vsphere commandline interface reference lists help information for all esxcli commands. Notes, the custom image isos listed below are custom vmware esxi 5. The extensive detail is very useful for troubleshooting and gathering information about the system. First of all you have to grab the hp smart array drivers and the hpacucli utility in the vib format.
When you type the command hpacucli, it will display a prompt as shown below where you can enter all the hpacucli commands explained in the article. Vmware hp raid controller commands cli systeembeheer voor. If vmware powercli is installed on a view connection server instance, the vmware powercli cmdlets load when you launch view powercli. You can refer to virtual machines and vcenter server instances by id in view powercli, but you cannot pass these entities as objects.
Download the hpe esxi offline bundles and thirdparty driver bundles included in the hpe customized image. To run hpacucli utility, user has to login into the command prompt on the esxi. The set of esxcli commands available on a host depends on the host configuration. Jul 11, 2012 binary royale is an it consultancy company based in the east midlands. How to run array diagnostic utility adu or hp insight diagnostics hp insight diagnostics to collect array status data or logs fro an esxi server how to. Problem we are facing is that hpacucli no longer seems to work in this new combination, e. Lazysystemadmin is a useful howto website that covers system administration, operating systems, cloud, devops, virtualization, scripts and video tutorials. The horizon helpdesk utility is designed to be a tool used by real help desk agents. Recommended hpe esxi utilities offline bundle for vmware vsphere 6. Recommended hpe esxi offline bundle for vmware vsphere 6. Ive installed 4 new hard disks on it and want to put them in a raid 6 array although raid 10 would be ok too.
If youve migrated to a newer kernel and a newer hpsa module is used instead of cciss, you may wonder why youre no longer able to use hpacucli tool to see the status of your raid device. Migrate raid0 to raid1 online with hpacucli hewlett packard. How to monitor the hp smart array configuration on an. Jul 22, 2014 to use hpacucli, download and install the latest version of hpacucli rpm from the hp website on your linux server. Ive installed 4 new hard disks on it and want to put them in. Hpssacli can be used in the configuration of hpe smart array controllers and. Ma ho pensato, visto che hp offre i software di gestione per i suoi controller raid su windows o linux, controlliamo che non ci sia qualcosa anche per vmware esxi.
By downloading, you agree to the terms and conditions of the hewlett packard enterprise. The offline bundle can also be installed from vmware vcenter update manager as a patch. You can directly download this hpacucli utility and install on the esxi server to gather the information of the server. And i finally reboot the server in order to complete the installation, hopefully. If you want to install only the raid utility, look for the hpacucli vib file. Hpe smart array cli commands on esxi kalles playground. A blog about linux and hp unix smart solutions and technical solutions. Vmware cloud foundations single stack of compute, network, storage, and security allows centurylink to continue to compete in a softwaredefined world, with less time spent on infrastructure deployments and more time on. The working answer for debian jessie administrators, and mainly those who own hp proliant ml350 gen9 is to use the command hpssacli. Did you know, you can do all sorts of funky stuff with hpacucli.
Once you have purchased vmware view, you will receive a license confirmation email with your license keys or you can retrieve your license keys from the vmware license portal. Feb 19, 20 hp array configuration utility cli for linux. Hpe proliant smart array controller driver for vmware vsphere 6. Hi all, ive got an hp dl360 g5 server which is running vmware esxi 5. I am specifically interested in finding out whether the disks are sas or sata, and whether the p410i controller is equipped with nvram and a battery. Dec 06, 2016 esxcli s u root p mypassword software vib remove n installing offline bundles on an vsphere 6. Cim providers for all the hardware is available you may use the oem versions of esxi which can be downloaded from the download vmware vsphere hypervisor based on esxi. Download vmware horizon with view vmware horizon with view select version. Organizations use workstation player to deliver managed corporate desktops, while students and educators use it for learning and training. To view the status of the controller, disks or volumes you can run all sorts of commands to get information about what is going on in your vmware esxi server. Customers who have purchased vmware horizon can download their relevant installation package from the product download tab below. Hewlettpackard vmwareaccepted hpacucli hewlettpackard. Unfortunately there is a flashing amber light on the front of 1 of the disk drives and from the service manual i have, it states that the disk is faulty and should be replaced immediately.
Migrate raid0 to raid1 online with hpacucli hello everyone can someone confirm me that following will work as expected without data loss, please. Vmware delivers virtualization benefits via virtual machine, virtual server, and virtual pc solutions. Hello, i would like to know, how find the biosfirmware revision of smart array card with a linux command line. Download vmware workstation player for free today to run a single virtual machine on a windows or linux pc. How to run the hp online acu cli for linux in esxi 4.
Check the raid rebuild status with hpacucli from esxi on hp servers. I noticed that this post still gets a lot of attention. You can donwload hpacucli utility directly and upload the vib file into your esxi host and execute the below command to install the. How to generate hp adu disk report in esxi host vmware arena. By downloading, you agree to the terms and conditions of the hewlett packard. How do i manage the hp raid controller without rebooting the server and going into the controller bios. Customers who have purchased vmware view can download their relevant installation package from the product download tab below. After searching the net for almost a whole day, i found this page saying that hpacucli is not working. Oct 18, 2012 also, every reboot cycle is really time consuming. How to view hp smart array firmware version on hp proliant bl460c blade server.
Server operating systems and virtualization software for hpe. We are running several servers with p410i controller. Migrate raid0 to raid1 online with hpacucli hewlett. Download and save hpacucli in to your pc and launch the winscp, use your esxi ip, username and password to connect to the server and copy hpacucli 9. The horizon helpdesk utility takes all of the functionality of the current html5 based helpdesk in vmware horizon and adds true desktop integration features, including. How to monitor the hp smart array configuration on an vmware. Check the raid rebuild status with hpacucli from esxi on hp. Well, you can just install the server using the regular vmware installation iso, and try to add the hp offline bundles after the installation. Run esxcli server help before you run a command on a host to verify that the command is defined on the host you are targeting. Firstly download the hp esxi utilities offline bundle for vmware vsphere 6. Running hpacucli inside esxi is of course not supported by hp or vmware. How do i manage an hp raid controller when running esxi.
But how can you install the hp packages for monitoring and the hpacucli tool if you are not able to install the box with the hp customized iso. How to monitor the hp smart array configuration on an vmware esxi host. Solved hp tools acu, adu on windows server 2012 spiceworks. Hello, is there any way to check disk status from linux. Need to find the raid status of an hp server running esxi.
May 15, 20 but how can you install the hp packages for monitoring and the hpacucli tool if you are not able to install the box with the hp customized iso. First is that the hpacucli is not available yet in a full 64 bit package, but relies instead upon that platforms 32 bit compatibility libraries. How to configure hp ilo from esxi host vmware arena. Hi i need help i am new to the hp proliant dl380 g3 i got it cheap and want to use it as a server at home i have 4 hd in raid 1 all are 72gb hd. Id say that the op would be better served opening a case with hps support group, but hps support of linux has proven to be infuriatingly poor. First, i checked on hp website and there was some promising download. Aug 07, 20 where can the hpacucli utilties for an esxi 4. Hpacucli can be used in the configuration of hp smart array controllers and attached storage. How to view hp smart array firmware version on hp proliant. Apply bundles to your vmware esxi downloaded from vmware. Manage an hp smart array directly from vmware esxi. Sul sito hp cera effettivamente qualche download interessante. We spend all of our time with clients, helping them to make good decisions about their it.
Click here to view the document titled vmware esxi 5. How to check disk status hewlett packard enterprise. It downloads the hp esxi utilities offline bundle zip file. Dell openmanage server administrator can be used to view the hardware health information. I know in hpux i can check if mirror works fine, but can i do the same with linux. The download of each custom image iso includes two separate end user license agreements eulas for the end user to accept. To use hpacucli, download and install the latest version of hpacucli rpm from the hp website on your linux server.
For more information, see the document titled vmware esxi 5. Its not a redhat issue, its an issue with the crap job that hp does with packaging the proliant support pack psp. Vmware horizon clients for windows, mac, ios, linux, and android allow you to connect to your vmware horizon virtual desktop from your device of choice giving you on. I have down load this file hpacucli and copy to esxi data store.
Before reading through the whole post you should know. This website to share our expertise and knowledge on linux, unix, windows, hardware, security, cloud and open source. You can of course view it first should you want it. Feb 17, 2014 hp tools acu, adu on windows server 2012. I can tell you that it just works for me in the configurations that i was able to test, but it could as well fail completely for you or blow up your host. Apparently you can install hpacucli in esxi very easily, and whats even better is that you can install it directly on a datastore and use the install on any continue reading how to use hpacucli in esxi. We have some servers in other building and we want to monitor disk status remotelly. By downloading, you agree to the terms and conditions of the hewlett packard enterprise software license agreement. Is it correct when i assume i need to install hpacucli to add the hd or partitions. Vmware workstation pro is the industry standard for running multiple operating systems on a single linux or windows pc workstation 15. Some software requires a valid warranty, current hewlett packard enterprise support contract, or a license fee. Im looking for some assistance in creating a new raid5 and logical drive from 4 new 900gb sas drives recently added to a hp dl380 g7 server using the hpacucli command there is already a raid1 consisting of x2 146gb drives that contains the esxi 5. The required program to be able to talk to the smart array is called hpacucli. This is a description on how to check the status of a hp smart array and report disk failures by email from the esx i host using hp command line utilities fur this purpose, the hpssacli utility will be used, which is part of hp esx i utilities offline bundles, but also part of customised hp esx i images for proliant servers.
310 995 710 1536 1470 1479 1066 1214 885 510 1206 590 549 1078 504 1608 257 978 1268 284 812 908 1393 121 731 936 930 1386 18 1305 1255 1055 855 36